Answers are grounded in this paper and cite their sources.
Oxidation of silicon in a radio frequency discharge oxygen plasma was studied using in situ during process rapid ellipsometry (1 s resolution and interval). Plasma characteristics were also determined by the Langmuir probe method and emission spectroscopy. From the measurement of in situ during process rapid ellipsometry, oxidized film thickness of silicon increased steeply right after starting rf discharge and slowly after ≊3000 s. It was found that thickness change rate measured by in situ during process rapid ellipsometry immediately after starting the rf discharge was strongly proportional to O2+ ions density.
No takes yet. Share an insight, caveat, or question.
Kuroki et al. (1992) studied this question.