Answers are grounded in this paper and cite their sources.
In studies to improve the efficiency of absorption machines, the generator/absorber heat-exchange (GAX) cycle is one of the main ways of using internal heat recovery without over-complicating the system. In this paper, the different architectures of the GAX cycle studied from 1986 to 2023 have been synthesized and analyzed. The standard GAX cycle is the most studied. In addition, by adding a pump or a compressor, branched GAX and hybrid GAX cycles have also been studied with a coefficient of performance (COP) improvements by up to 30%. In addition, the overview provides details of assumptions in the numerical studies used to simulate operation of the GAX cycle. Experimental results obtained from the literature prototypes are also introduced. A new method to compare the COP obtained in different studies, which depends on the driving force (DF) and the gross temperature lift (GTL) is presented. This method is easy to be implemented, giving a rapid interpretation of the results. Experimental results show that in the chiller mode when DF is 100 °C and GTL decreases from 40 to 25 °C, COP increases from 0.39 to 0.54. Meanwhile, in the heat pump mode when DF increases from 125 to 140 °C and DF decreases from 50 to 35 °C, COP increases from 1.60 to 1.73.
No takes yet. Share an insight, caveat, or question.
Pham et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: