Why the study?
Do cardiac IL-6 levels at the time of implantation predict post-operative outcomes in LVAD recipients compared to plasma IL-6 and CRP?
Observational (n=40)
Do cardiac IL-6 levels at the time of implantation predict post-operative outcomes in LVAD recipients compared to plasma IL-6 and CRP?
Answers are grounded in this paper and cite their sources.
Cardiac tissue IL-6 levels at the time of LVAD implantation do not predict early post-operative outcomes, whereas circulating plasma IL-6 and CRP remain effective prognostic markers.
BACKGROUND: In left ventricular assist device (LVAD) recipients, plasma levels of interleukin (IL)-6 are associated with Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profiles, reflecting post-operative risk. However, it is not clear how the cardiac level of IL-6, detectable on the tissue samples at the time of implantation, can contribute to predict the post-operative outcome. METHODS: In 40 LVAD recipients, blood and myocardial samples from LV-apex were collected at the time of implantation to assess plasma and cardiac IL-6 levels. Serum C-reactive protein (CRP) levels were considered as inflammatory variable routinely used in LVAD-based therapy. RESULTS: Cardiac IL-6 levels did not correlate with either plasma IL-6 levels (R=0.296, p=0.063) and tissue IL-6 mRNA expression (R=-0.013, p=0.954). Contrary to what happened for the plasma IL-6 and CRP, no differences were observed in cardiac IL-6 levels with respect to INTERMACS profiles (p=0.090). Furthermore, cardiac IL-6 concentrations, unlike IL-6 and CRP circulating levels, were not correlated with the length of intensive care unit stay and hospitalization. CONCLUSIONS: Cardiac IL-6 levels do not contribute to improve risk profile of LVAD recipients in relation to clinical inpatient post-implantation. Instead, plasma IL-6 and serum CRP concentrations are more effective in predicting the severity of the clinical course in the early phase of LVAD therapy.
No takes yet. Share an insight, caveat, or question.
Caruso et al. (2014) conducted an observational in Left ventricular assist device (LVAD) recipients (n=40). Cardiac IL-6 levels was evaluated on Correlation between cardiac IL-6 levels and plasma IL-6 levels (R 0.296, p=0.063).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: