Answers are grounded in this paper and cite their sources.
Aim: This can be done by computed tomography (CT), three dimensional implant planning software, image guided template production techniques, and computer aided surgery. Subjects and Methods: 20 implant placed in selected adult patients of both sexes ,divided into two groups. Group I: included 10 conventional implants placed in patients. Group II: Included 10 guided implants placed in patients (by using steriolithography.). Clinical photographs were taken before ,during and after procedures .Conebeam computed tomography was performed. Surgical procedure was done and implant were positioned. Implant evaluation clinically by implant primary stability by measuring the accuracy of the surgical guide on the postoperative image after implant insertion by recorded linear deviation(coronal ,apical )angular deviation ,and measurement of deviation in the post-operative implant position from the preoperative virtual implant planning. Results: We found noticeable high significant difference in group I than Group II in Coronal ,apical ,angular direction. Conclusion: The results proved the benefit of Using surgical guide template .
No takes yet. Share an insight, caveat, or question.
Makhlouf et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: