Key result
ICD shock and Type D personality are linked to poorer health status at 12 months.
Why the study?
Are ICD shock and preimplantation Type D personality associated with poorer health status in patients with an implantable cardioverter-defibrillator?
Cohort (n=383)
Are ICD shock and preimplantation Type D personality associated with poorer health status in patients with an implantable cardioverter-defibrillator?
Preimplantation Type D personality and ICD shock during follow-up are equally important independent predictors of poor health status 12 months after ICD implantation.
Answers are grounded in this paper and cite their sources.
May flag high-risk ICD patients for support; leaves open whether targeting shocks or Type D personality improves outcomes.
BACKGROUND: Implantable cardioverter-defibrillator (ICD) shock is a critical event to patients associated with well-being after implantation, although other factors may play an equally important role. We compared the association of shock and the patient's preimplantation personality with health status, using a prospective study design. METHODS AND RESULTS: Consecutively implanted ICD patients (n=383; 79% men) completed the Type D Scale at baseline and the Short-Form Health Survey 36 (SF-36) at baseline and 3, 6, and 12 months. Of all patients, 23.5% had a Type D personality and 13.8% received a shock during follow-up. Shocked patients reported significantly poorer health status, as did Type D patients. Health status patterns were poorest in patients with combined Type D personality and shock during follow-up. Shock during follow-up was a significant independent associate of poorer health status for 4 of 8 subscales of the SF-36 and the Mental Component Summary (all P<.05), with shocked patients scoring between 2.60 to 13.30 points lower than nonshocked patients. Type D personality was an independent associate of poor postimplantation health status for 6 of 8 of the SF-36 subscales and the Mental Component Summary, with Type D patients scoring between 2.12 to 8.02 points lower, adjusting for demographic and clinical characteristics. CONCLUSIONS: ICD shock and the patient's preimplantation personality disposition were equally important associates of health status 12 months after implantation. Identification of the patient's personality profile before ICD implantation may help identify subsets of patients who may need additional care, for example, with a psychosocial component.
No takes yet. Share an insight, caveat, or question.
Pedersen et al. (2012) conducted a cohort in Implantable cardioverter-defibrillator (ICD) patients (n=383). ICD shock and Type D personality vs. No shock and non-Type D personality was evaluated on Health status (SF-36 subscales and Mental Component Summary) (p=<.05). ICD shock and preimplantation Type D personality were independently associated with poorer health status at 12 months, scoring 2.60-13.30 and 2.12-8.02 points lower on SF-36 subscales, respectively.
Synapse has enriched 10 related papers. Consider them for comparative context: