Key result
Automated monitoring fails to prevent apnea or cardiopulmonary arrest during endoscopy despite earlier recognition.
Why the study?
Does finger pulse oximetry monitoring prevent apnea or cardiopulmonary arrest in patients undergoing endoscopy?
Observational (n=10,000)
Does finger pulse oximetry monitoring prevent apnea or cardiopulmonary arrest in patients undergoing endoscopy?
Automated monitoring with pulse oximetry during endoscopy does not prevent apnea or cardiopulmonary arrest but allows for earlier recognition of these complications.
Answers are grounded in this paper and cite their sources.
Automated monitoring does not prevent rare cardiopulmonary events during endoscopy; leaves open whether earlier recognition improves outcomes in large cohorts.
Ten patients developed apnea or cardiopulmonary arrest during or following endoscopy in more than 10,000 consecutive endoscopies. These complications occurred in patients over the age of 60 years with many associated diseases. Four of the reactions occurred close to the time of giving intravenous medication, the majority after the stimulation of the procedure had ended, usually more than 30 min after the last dose of medication. The initial 7,500 procedures were conducted without automated monitoring, but the most recent 2,500 procedures employed finger pulse oximetry. Monitoring has not prevented apnea and cardiopulmonary arrest, but it provides earlier recognition.
No takes yet. Share an insight, caveat, or question.
Iber et al. (1992) conducted an observational in Patients undergoing endoscopy (n=10,000). Automated monitoring (finger pulse oximetry) vs. No automated monitoring was evaluated on Apnea or cardiopulmonary arrest. Apnea or cardiopulmonary arrest occurred in 10 of over 10,000 endoscopies; automated monitoring provided earlier recognition but did not prevent these events.
Synapse has enriched 10 related papers. Consider them for comparative context: