Answers are grounded in this paper and cite their sources.
Introduction: The bacteriology-virology laboratory of the teaching university hospital of Brazzaville, was equipped with a real-time PCR device like Miniopticon (Biorad® , France). The aim of this work was to do an evaluation of the HIV viral load activity, with a view to proposing some recommendations. Material and methods: Retrospective study, January 2013 to March 2015, in patients on first line ARV three-therapy, pre-inclusion therapy checkup in HIV positive patients, but again screening after sexual abuse in women or accident of exposure (AES). A blood sample on EDTA tube was made and RNA extraction with Qiagen kit. Ultrasensitive HIV-RNA quantification was performed using the Generic HIV real-time PCR assay (Biocentric®, Bandol, France). Results: 126 patients were included. The mean age was 37.63 years +/- 10.43 years, sex ratio F/H = 2.3. The HIV viral load was detectable in 94 cases (74.6%). Concerning patients with detectable viral load (copies/ml): 403 to 996 in 35 cases (37.23%), 1411 to 1812 in 41 cases (43.62%) and >1814 in 5 cases (5.32%) (therapeutic failure). Conclusion: This work reports success in the setting up of the molecular biology unit. Procedures that implement information and education actions on the risks associated with AES must be disclosed.
No takes yet. Share an insight, caveat, or question.
Ngoyi et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: