We present an integrative method for studying alveolar fluid accumulation during pulmonary edema using scanning electron microscopy (SEM) of frozen‐hydrated lung. We induced edema in dogs by fluid over‐loading the vascular system while monitoring vascular and airway pressures. Terminally, we freeze‐fixed the lungs in the open thorax while controlling airway pressure. Using a cryosample preparation chamber attached to a scanning electron microscope equipped with a low temperature stage, we in vacuo freeze‐fractured the lung, gold coated the fractured surface and used secondary electron emission scanning electron microscopy to examine the frozen‐hydrated lung with scanning electron micrographs of freeze‐dried and airway fixed, critical point dried lung. We discuss the advantages of frozen‐hydrated scanning lung preservation for pulmonary edema research, especially in regard to quantifying alveolar fluid distribution by stereo photogrammetry, and suggest areas of future research to improve the method.