Key result
Device-measured health data significantly differs from self-reported metrics for Life's Simple 7 scores.
Why the study?
It was hypothesized that digital health devices provide a more objective assessment of cardiovascular health status than traditional self-reported measures.
Does data from digital health devices provide a significantly different assessment of ideal cardiovascular health compared to self-reported measures?
Observational (n=1,561)
Does data from digital health devices provide a significantly different assessment of ideal cardiovascular health compared to self-reported measures?
Absolute Event Rate: 7% vs 6.6%
p-value: p=<0.01
Incorporating digital health device data provides a more objective and significantly different assessment of cardiovascular health compared to self-reported surveys.
Device-based Life’s Simple 7 scores may offer objective metrics; leaves open validation against outcomes before clinical use.
Ideal cardiovascular health is associated with a decrease in adverse cardiovascular events. The My Research Legacy study examined ideal cardiovascular health using the Life’s Simple 7 survey and data from digital health devices. We hypothesized that digital devices provide a more objective view of overall cardiovascular health status than self-reported measures. Therefore, we analyzed weight and activity data recorded by digital devices to recalculate the Life’s Simple 7 Health Score. All study participants (n = 1561) answered the survey, while a subgroup (n = 390) provided data from digital devices. Individuals with digital devices had a lower body mass index (BMI) and higher weekly minutes of vigorous exercise than participants without digital devices (p < 0.01). Baseline Health Scores were higher in individuals with digital devices compared to those without (7.0 ± 1.6 vs. 6.6 ± 1.6, p < 0.01). Data from digital devices reveal both increases and decreases in measured vs. self-reported BMI (p < 0.04) and weekly minutes of moderate and vigorous exercise activity (p < 0.01). Using these data, a significant difference was found between the recalculated and the self-reported Life’s Simple 7 Health Score (p < 0.05). These findings suggest that incorporation of digital health devices should be considered as part of a precision medicinal approach to assessing ideal cardiovascular health.
No takes yet. Share an insight, caveat, or question.
Leopold et al. (2021) conducted an observational in Cardiovascular health (n=1,561). Digital health devices vs. No digital health devices (self-reported measures only) was evaluated on Baseline Life's Simple 7 Health Score (p=<0.01). Digital health device data revealed significant differences in measured versus self-reported metrics, leading to significantly different recalculated Life's Simple 7 Health Scores (P<0.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: