Key result
Valved composite graft aortic root replacement shows ~7% hospital mortality for aneurysm or dissection.
Why the study?
Does prosthetic aortic root replacement with a valved composite graft provide safe and effective outcomes in patients with aortic root aneurysm or dissection?
Cohort (n=335)
Does prosthetic aortic root replacement with a valved composite graft provide safe and effective outcomes in patients with aortic root aneurysm or dissection?
Composite graft replacement of the aortic root for aneurysm or dissection demonstrates acceptable early mortality (6.6%) and good long-term survival (80% at 5 years).
Answers are grounded in this paper and cite their sources.
Supports consideration of composite graft replacement for aortic root aneurysm or dissection; extends observational data but leaves open comparative effectiveness.
The hypothesis that replacement of the aortic root with a valved composite graft is a safe and effective therapy for aneurysms involving the sino-tubular segment of the aorta was tested by a retrospective review. From September 1978 to January 1995, 335 consecutive patients underwent prosthetic aortic root replacement as the primary operation for aneurysm (222) or dissection (acute 59, chronic 54). There were 248 men (74%) and 87 women (26%) with a mean age of 50 +/- 14 years. 22 patients (6.6%) experienced hospital death primarily due to cardiac causes. Mortality was significantly higher in patients with acute dissection versus those with non-dissecting aneurysms and chronic dissection. Sex, Marfan syndrome (20.3% of patients), mitral regurgitation, coronary artery disease, and era of operation had no effect on early outcome. Mortality was significantly increased in patients aged over 50 years, in those with circulatory compromise, and in patients requiring emergency operation. Follow-up was complete in 313 survivors (97%) at a mean of 61.3 +/- 44 months. Actuarial survival was 80% at 5 and 67% at 10 years. There were no complications involving the coronary anastomoses, other than infection-related, regardless of the mode of ostial reattachment.
No takes yet. Share an insight, caveat, or question.
Mingke et al. (1998) conducted a cohort in Aneurysm or dissection involving the sino-tubular segment of the aorta (n=335). Replacement of the aortic root with a valved composite graft was evaluated on Hospital death. Prosthetic aortic root replacement with a valved composite graft for aneurysm or dissection resulted in a 6.6% hospital mortality rate and an actuarial survival of 80% at 5 years and 67% at 10 years.
Synapse has enriched 10 related papers. Consider them for comparative context: