Key result
Modified gamma nail with tri-wire anchorage linked to 100% fracture union and excellent functional outcomes.
Why the study?
Pertrochanteric fractures commonly cause deterioration in quality of life in elderly patients until stabilized, prompting evaluation of a modified gamma nail with additional tri-wire anchorage to stabilize rotational torque.
Does modified gamma nail with tri-wire anchorage improve functional and radiological outcomes in patients with per-trochanteric fracture?
Observational (n=39)
No
Does modified gamma nail with tri-wire anchorage improve functional and radiological outcomes in patients with per-trochanteric fracture?
Modified gamma nail with tri-wire anchorage provides excellent functional outcomes and a 100% union rate for per-trochanteric fractures.
Should not yet change per-trochanteric fracture fixation practice; leaves open need for RCTs to confirm benefit of tri-wire anchorage.
Background: Pertrochanteric fractures comprise almost 50% of all proximal femoral fractures. Being common in elderly people, the quality of life deteriorates until the fracture is stabilized, followed by early mobilization. Intramedullary devices have been proven to improve biomechanics. In our study, we adopted modified gamma nail with additional tri-wire anchorage construct, which further stabilizes the rotational torque. Methods: A prospective study was undertaken on 39 skeletally mature patients of both sexes, with per-trochanteric fracture, from January 2019 to April 2020. The study included 23 females and 16 males. the 34 underwent CRIF while 5 underwent ORIF. One patient was lost to follow-up. Clinico-radiological evaluations of the patients were done for 12 months. Functional evaluation was based on the modified Harris hip score (mHHS). Statistical analysis was done by SPSS (version 27.0; SPSS Inc., Chicago, IL, USA) and GraphPad Prism version 5. Results: The study showed 100% union rate. Radiologically at 3 months, the fracture united in all patients. At 6 months postoperatively all patients were ambulatory with or without walking aids. One patient had tri-wire cut through and one had tri-wire back-out. HHS was an average of 79 at 3 months representing a fair outcome. This increased to 90 at 6 months representing an excellent outcome. Conclusions: Modified gamma nail with tri-wire anchorage has distinct advantages over other techniques. It allows for early weight-bearing and mobilization with lesser complications. The tri-wire construct further provides additional rotational stability in osteoporotic bone. nal stability in osteoporotic bone.
No takes yet. Share an insight, caveat, or question.
Mukherjee et al. (2022) conducted an observational in Per-trochanteric fracture (n=39). Modified gamma nail with tri-wire anchorage was evaluated on Modified Harris hip score (mHHS) at 6 months. Fixation of per-trochanteric fractures using a modified gamma nail with tri-wire anchorage resulted in a 100% union rate at 12 months and an excellent functional outcome with a mean modified Harris hip score of 89.8 at 6 months.