Key result
ICDs deliver appropriate therapies in ~42% of patients with Chagas disease over 12 months.
Why the study?
Does an implantable cardioverter defibrillator (ICD) effectively terminate life-threatening arrhythmias in patients with Chagas' disease?
Observational (n=89)
Yes
Does an implantable cardioverter defibrillator (ICD) effectively terminate life-threatening arrhythmias in patients with Chagas' disease?
ICD therapy provides effective protection by terminating life-threatening arrhythmias in patients with Chagas' disease, particularly for secondary prevention.
May support ICD consideration for arrhythmia termination in Chagas' disease; leaves open survival benefit pending randomized trials.
AIMS: Chagas' disease is an endemic parasitic affliction in Latin America. It is frequently associated with ventricular tachyarrhythmia and sudden death. The aim of this study is to assess the evolution of patients with Chagas' disease treated with an implantable cardioverter defibrillator (ICD). METHODS AND RESULTS: Eighty-nine chagasic patients with ICD were included for analysis from the Medtronic ICD Registry Latin America. At implant, mean age was 59 +/- 10 years, and 72% were male. Eighty-one patients (91%) had secondary prevention indications. Mean left ventricular ejection fraction was 40 +/- 11%, and mean follow-up was 12 +/- 7 months. During follow-up, six patients died (6.7%); three due to congestive heart failure, one due to sudden death, and two due to non-cardiac cause. Hospitalization occurred in seven patients. Thirty-eight patients (42%) received appropriate ICD therapies. A total of 737 episodes were detected by the ICD. The mean period between ICD implantation and the first appropriate therapy was 104 days. Electrical storms were observed in 14 of the 89 patients (15.7%). Inappropriate therapies were observed in seven patients. CONCLUSION: This registry confirms that ICD therapy provides protection by effectively terminating life-threatening arrhythmias in patients with Chagas' disease. This is especially so when patients receive the device for secondary prevention.
No takes yet. Share an insight, caveat, or question.
Muratore et al. (2008) conducted an observational in Chagas' disease (n=89). Implantable cardioverter defibrillator (ICD) was evaluated on Appropriate ICD therapies. Implantable cardioverter defibrillators delivered appropriate therapies in 42% of patients with Chagas' disease over a mean follow-up of 12 months, with an overall mortality rate of 6.7%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: