Answers are grounded in this paper and cite their sources.
The large inventory of tritium in cryogenic distillation columns is a significant hazard and presents a design and operational challenge for future fusion power stations. It is not possible to accurately predict the liquid holdup in these columns because there are no available experimental datasets or validated models for liquid hydrogen fluids on structured packings. In this paper, we demonstrate that liquid nitrogen may reasonably be used as a proxy for liquid hydrogen for prediction of holdup in the preloading regime based on similarity of kinematic viscosity. We present a new first-principles-derived semi-empirical model for the prediction of liquid holdup in the preloading regime. It incorporates the effect of vapour velocity below the loading point and it introduces a new representation of the liquid fall angle across inclined packings that reduces the predicted holdup by up to 5 %. This model is compared to existing models and, for the first time, these are validated against experimental data using liquid nitrogen as a proxy for fusion hydrogen. The new semi-empirical model is shown to outperform established empirical models which appear to overestimate the liquid inventory by between 14 – 57 %. The new model fits the liquid nitrogen data with an R 2 of 0.826 ahead of 0.642 for the next best performing model.
No takes yet. Share an insight, caveat, or question.
Rouvas et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: