Key result
Modified end-to-side CABG improves hemodynamics over conventional configurations but increases structural vessel wall stress.
Why the study?
Disrupted flow causes intimal thickening in end-to-side CABG, but existing reconfigurations require complex in situ graft manipulations not suited for surgery.
Does a modified bed shape configuration improve hemodynamics in end-to-side CABG compared to conventional configuration?
Does a modified bed shape configuration improve hemodynamics in end-to-side CABG compared to conventional configuration?
A simple geometric modification to the host artery bed in ETS CABG may improve local hemodynamics and potentially reduce intimal thickening, though it increases structural wall stress.
Answers are grounded in this paper and cite their sources.
Modified ETS CABG bed may improve animal hemodynamics; hypothesis-generating and should not change practice pending human data.
Disrupted flow initiates and aggravates intimal thickening in the end-to-side (ETS) coronary artery bypass grafting (CABG), which may lead to failure. To enhance the post-intervention hemodynamics, the geometry is either optimized or totally reconfigured. Majority of configurations proposed by researchers have not suited CABG surgery, for they entailed rigorous manipulation on conventional grafts in situ, which was neither swift nor straightforward. The aim of the present study is, thus, to introduce a slight, yet effective, modification to a conventional ETS CABG configuration, and numerically investigate its effects on updated hemodynamic and structural environment, anticipating the longevity of proposed configuration and CABG success. This fairly simple modification may easily be made positioning a pre-designed anastomotic device between the bed of host artery in the conventional ETS CABG and its surrounding tissues. Conducting comprehensive numerical simulations, performance of the proposed configuration was assessed using idealized and patient-specific geometries of the conventional ETS CABG. Blood flow was simulated in a conventional and an updated CABG configuration considering 2-way fluid–structure interaction. Results revealed that, although the proposed configuration may induce higher structural stresses in vessels walls, it may improve important hemodynamic metrics such as wall shear stress gradient, oscillatory shear index, and relative residence time on host artery bed reducing disruption of flow. This study may also set the stage for design engineers and regulatory officials to evolve ETS CABG toward more hemodynamics-friendly approaches. Further in vitro, preclinical, and clinical experiments are, yet, entailed to accomplish ideal designs of procedural guidelines/grafts.
No takes yet. Share an insight, caveat, or question.
Ramezanpour et al. (2019) studied Coronary artery bypass grafting (CABG). Modified end-to-side CABG configuration vs. Conventional end-to-side CABG configuration was evaluated on Hemodynamic metrics (wall shear stress gradient, oscillatory shear index, relative residence time) and structural stresses. A modified end-to-side CABG configuration improved hemodynamic metrics like wall shear stress gradient and oscillatory shear index, though it induced higher structural stresses in vessel walls.
Synapse has enriched 10 related papers. Consider them for comparative context: