Why the study?
Does aortic valve replacement with the freedom SOLO bioprosthesis cause clinically significant postoperative thrombocytopenia in patients undergoing AVR?
Cohort (n=254)
Yes
Does aortic valve replacement with the freedom SOLO bioprosthesis cause clinically significant postoperative thrombocytopenia in patients undergoing AVR?
Answers are grounded in this paper and cite their sources.
Thrombocytopenia following aortic valve replacement with the freedom SOLO bioprosthesis is a transient, benign postoperative phenomenon without adverse clinical consequences.
The aim of the study was to investigate the multi-factorial phenomenon of possible postoperative thrombocytopenia after aortic valve replacement (AVR) with the freedom SOLO (FS) bioprosthesis. A total of 254 patients underwent AVR with FS bioprosthesis in two cardiac surgery institutes. Platelet counts were measured preoperatively, immediately postoperatively and daily until the 11th day postoperatively. A multivariate generalized estimating equation model was applied to identify prognostic factors for whether or not patients postoperative platelet counts indicated no thrombocytopenia (platelet count >150 10(3)/mm(3)) versus at least mild thrombocytopenia (≤150 10(3)/mm(3)). Preoperatively, 11.2% of patients showed thrombocytopenia. The preoperative platelet count averaged 233.0 ± 83.2 10(3)/mm(3). The postoperative mean of platelet counts decreased daily reaching a minimum mean of 88.4 ± 58.8 10(3)/mm(3) 3 days after surgery and then started to increase, with the Day 11 postoperative mean of 173.3 ± 51.8 10(3)/mm(3). Compared with patients with no preoperative thrombocytopenia, patients with preoperative thrombocytopenia had an 8.69 increased odds of being in the group with postoperative platelet count <150 10(3)/mm(3). No major haemorrhagic or thromboembolic event was reported during hospitalization. This study shows that thrombocytopenia after the FS bioprosthesis replacement is a transient postoperative phenomenon, largely resolved within a few days after surgery, with no clinical consequences and haemodynamic dysfunction.
No takes yet. Share an insight, caveat, or question.
Repossini et al. (2012) conducted a cohort in Aortic valve replacement (n=254). Preoperative thrombocytopenia vs. No preoperative thrombocytopenia was evaluated on Postoperative platelet count <150 10(3)/mm(3) (OR 8.69).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: