Key result
Non-thoracotomy ICD implantation achieves ~91% success without an epicardial patch and reliably terminates arrhythmias.
Why the study?
Does non-thoracotomy ICD implantation provide reliable arrhythmia termination and prevent sudden cardiac death in high-risk patients?
Cohort (n=110)
Does non-thoracotomy ICD implantation provide reliable arrhythmia termination and prevent sudden cardiac death in high-risk patients?
Non-thoracotomy ICD implantation is highly successful, with low perioperative mortality and reliable termination of ventricular arrhythmias.
Supports non-thoracotomy ICD feasibility in high-risk patients; leaves open comparative SCD prevention versus epicardial systems.
Non-thoracotomy implantation of implantable cardioverter defibrillators (ICDs) has simplified the process of device insertion, promising to decrease associated procedural complications while providing sudden death protection at least equal to epicardial systems. This study presents the acute and chronic results of 110 patients who underwent attempted non-thoracotomy ICD implantation with the Medtronic Transvene lead system and PCD model 7217 or 7219. Of the 110 patients attempted, 100 (91%) had the system successfully implanted without the need for an epicardial patch. One patient died 1 week postoperatively of septic shock related to the implantation (0.9% perioperative mortality). During follow-up of 16 +/- 11 months, 45% of the patients had an event detected as ventricular tachycardia; 26% of these detections were felt clinically to be due to supraventricular rhythms. Of the remainder, 87% were successfully treated with the first VT therapy, and 98% were terminated by the final therapy; 66% of the patients had at least one episode of ventricular fibrillation, of which 5% were felt to be inappropriate detections; 85% of the appropriate episodes were successfully treated with the first VF therapy, and all were converted by the final therapy. Total mortality at 6, 12, and 24 months was 3%, 11%, and 19% respectively. Only one patient had sudden cardiac death, occurring at 13 months postimplant. Overall, the non-thoracotomy lead system for this ICD displayed infrequent implant complications and proved to be reliable at terminating arrhythmias and maintaining a low rate of sudden cardiac death in this high risk population.
No takes yet. Share an insight, caveat, or question.
Brachmann et al. (1994) conducted a cohort in High risk for sudden cardiac death requiring ICD (n=110). Non-thoracotomy ICD implantation (Medtronic Transvene lead system) was evaluated on Successful implantation without the need for an epicardial patch. Non-thoracotomy ICD implantation was successfully performed in 91% of patients without an epicardial patch, demonstrating reliable arrhythmia termination and a 19% total mortality at 24 months.