Answers are grounded in this paper and cite their sources.
In this paper, density, viscosity, and speeds of sound measurements are presented for ethylenediamine (EDA) + water and diglycolamine (DGA) + water at amine weight concentrations from 0.1 to 0.4 in different temperature and atmospheric pressure ranges. Densities were measured using a vibrating tube densimeter (Rudolph Research Analytical, DDM-2911) with an accuracy of 0.05 kg·m−3. Viscosity measurements were obtained using a Sine-wave Vibro Viscometer SV-10 (A&D Company, Limited, Japan) with an expanded uncertainty (k = 2) of 0.017 which was calibrated with water. Ultrasonic velocities were measured by a single crystal, variable path interferometer purchased from Mittal Enterprises (Model No.SE-02) with an expanded uncertainty (k = 2) of 0.003.
No takes yet. Share an insight, caveat, or question.
Concepción et al. (2023) studied this question.