Key result
Head rotation linked to altered carotid vessel center lines and wall shear stress.
Why the study?
Does head rotation alter carotid geometry and hemodynamics in young adults?
Observational (n=9)
Does head rotation alter carotid geometry and hemodynamics in young adults?
Head rotation significantly alters carotid geometry and hemodynamics, highlighting the need for standardized head positioning during 3D ultrasound scans.
Answers are grounded in this paper and cite their sources.
May influence carotid hemodynamic measurements; leaves open standardization benefits for clinical ultrasound protocols.
Studies in adults have shown marked changes in geometry and relative positions of the carotid arteries when rotating the head. The aim of this study was to quantify the change in geometry and analyze its effect on carotid hemodynamics as a result of head rotation. The right carotid arteries of nine young adult subjects were investigated in supine position with straight and left turned head positions, respectively. The three-dimensional (3D) carotid geometry was reconstructed by using 3D ultrasound (3D US), and the carotid hemodynamics were calculated by combining 3D US with computational fluid dynamics. It was observed that cross-sectional areas and shapes did not change markedly with head rotation, but carotid vessel center lines altered with planarification of the common carotid artery as a main feature (P < 0.05). Measured common carotid flow rates changed significantly at the individual level when the head was turned, but on the average, the change in mean common carotid flow rate was relatively small (0.37 +/- 1.11 ml/s). The effect of the altered center lines and flow rates on the atherogenic nature of the carotid bifurcation was evaluated by using calculated hemodynamic wall parameters, such as wall shear stress (WSS) and oscillatory shear index (OSI). It was found that WSS and OSI patterns changed significantly with head rotation, but the variations were very subject dependent and could not have been predicted without assessing the altered geometry and flow of the carotid bifurcation for individual cases. This study suggests that there is a need for standardization of the choice of head position in the 3D US scan protocol, and that carotid stents and emboli diverters should be studied in different head positions.
No takes yet. Share an insight, caveat, or question.
Glor et al. (2004) reported an observational. Head rotation vs. Straight head position was evaluated on Carotid vessel center lines alteration (p=<0.05). Head rotation altered carotid vessel center lines and hemodynamic wall parameters like wall shear stress, with highly subject-dependent variations.
Synapse has enriched 10 related papers. Consider them for comparative context: