Key result
RUDI resolves a case of fistula-related high output cardiac failure in a hemodialysis patient.
Revision using distal inflow (RUDI) is presented as a treatment for fistula-related high output cardiac failure in a hemodialysis patient.
Potential option for fistula-related high-output HF; single case report leaves open need for prospective validation.
In patients on hemodialysis, cardiovascular disease can be precipitated or worsened by the presence of a high flow arteriovenous fistula. Fistula closure and banding are the traditional treatment methods of dialysis associated high output cardiac failure. We present a case of fistula-related high output cardiac failure treated by revision using distal inflow (RUDI).
No takes yet. Share an insight, caveat, or question.
Parmar et al. (2009) studied this question. Revision using distal inflow (RUDI) was successfully utilized to treat a case of fistula-related high output cardiac failure in a hemodialysis patient.