Key result
An EHR best practice alert increases EP referrals by ~23% and drives more ICD therapy.
Why the study?
ICDs are indicated for patients with left ventricular ejection fraction ≤35%, but many eligible patients do not receive this therapy.
Does an automated best practice alert through the electronic health record improve rates of electrophysiology referrals and ICD implantations in patients with severe cardiomyopathy?
RCT (n=1,906)
Cluster randomized
Does an automated best practice alert through the electronic health record improve rates of electrophysiology referrals and ICD implantations in patients with severe cardiomyopathy?
An automated electronic health record best practice alert significantly increases electrophysiology referrals and ICD implantations in eligible patients with reduced LVEF.
Answers are grounded in this paper and cite their sources.
EHR alerts warrant implementation to increase appropriate ICD use in severe cardiomyopathy; extends evidence for decision-support tools in heart failure.
Background Implantable cardioverter-defibrillators (ICDs) are indicated in patients with left ventricular ejection fraction ≤35%, but many eligible patients do not receive this therapy. In this cluster randomized trial, we investigated the impact of a best practice alert (BPA) through the electronic health records on the rates of electrophysiology referrals, ICD implantations, and all-cause mortality in severe cardiomyopathy patients. Methods and Results Providers in the Heart and Vascular Institute (n=106) and in General Internal Medicine (n=89) were randomized to receive or not receive a BPA recommending consideration for ICD implantation. Patients belonging to the BPA and no BPA groups of providers were followed to the end points of electrophysiology referrals, ICD implantations, and all-cause mortality. Between 2013 and 2015, patients with reduced left ventricular ejection fraction were managed by 93 providers in the BPA (n=997 patients) and 102 providers in the no BPA (n=909 patients) groups. Patients in the 2 groups had comparable baseline characteristics. After a median follow-up of 36 months, 638 (33%) patients were referred to electrophysiology, 536 (27%) received an ICD, and 445 (23%) died. Patients in the BPA group were more likely to be referred to electrophysiology (hazard ratio=1.23; P=0.026), to receive ICD therapy (hazard ratio=1.35; P=0.006), and exhibited a trend towards slightly lower mortality (hazard ratio=0.85; P=0.091). Conclusions Delivering a BPA through the electronic health record recommending to providers consideration of ICD implantation when the left ventricular ejection fraction is ≤35% improves the rates of electrophysiology referrals and ICD therapy in patients with severe left ventricular dysfunction.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2019) conducted an RCT in Severe cardiomyopathy with reduced left ventricular ejection fraction (n=1,906). Electronic health record best practice alert (BPA) vs. No best practice alert was evaluated on Electrophysiology referrals (HR 1.23, p=0.026). An electronic health record best practice alert recommending ICD implantation increased electrophysiology referrals and ICD therapy.
Synapse has enriched 10 related papers. Consider them for comparative context: