Answers are grounded in this paper and cite their sources.
In this study thermal performance of corrugated plate heat exchanger (PHE) in single-phase flow is carried out using the ANSYS CFX software.Aim of this research is to develop a generalized Nusselt Number correlation for a commercial PHE configuration under single-phase flow for two different chevron angle plates, 30 o /30 o and 60 o /60 o .The steady state simulation is carried out for a Reynolds number range of 500 to 2500, and the Prandtl number range of 3.5 to 7.5 is maintained in the simulation.The results showed that Nusselt number is increased with increasing Reynolds number as well as by increasing the chevron angle.However, Prandtl number showed trivial impact on the Nusselt number.
No takes yet. Share an insight, caveat, or question.
Asif et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: