Key result
Iodine staining-enhanced micro-CT successfully quantified 3D compact myocardial wall thickness, revealing significantly thinner compact myocardium in e12.5 p27-/- knockout mice compared to wild-types.
Absolute Event Rate: 49% vs 68%
p-value: p=2E-05
Iodine staining-enhanced micro-CT provides a non-destructive, quantitative 3D method to assess compact myocardial wall thickness and non-compaction in mouse embryos.
Enables 3D phenotyping of compaction defects in mouse embryos; leaves open translation to human non-compaction cardiomyopathy.
BACKGROUND: Ventricular non-compaction is characterized by a thin layer of compact ventricular myocardium and it is an important abnormality in the mouse heart. It is reminiscent of left ventricular non-compaction, a fairly common human congenital cardiomyopathy. Non-compaction in transgenic mice has been classically evaluated by measuring the thickness of the compact myocardium through histological techniques involving image analysis of 2-dimensional (D) sections. Given the 3D nature of the heart, the aim of this study was to determine whether a technique for the non-destructive, 3D assessment of the mouse embryonic compact myocardium could be developed. METHODS AND RESULTS: Micro-computed tomography (micro-CT), in combination with iodine staining, enabled the differentiation of the trabecular from the compact myocardium in wild-type mice. The 3D and digital nature of the micro-CT data allowed computation anatomical techniques to be readily applied, which were demonstrated via construction of group atlases and atlas-based descriptive statistics. Finally, micro-CT was used to identify the presence of non-compaction in mice with a deletion of the cell cycle inhibitor protein, p27(Kip1). CONCLUSIONS: Iodine staining-enhanced micro-CT with computational anatomical analysis represents a valid addition to classical histology for the delineation of compact myocardial wall thickness in the mouse embryo. Given the quantitative 3D resolution of micro-CT, these approaches might provide helpful information for the analysis of non-compaction. (Circ J 2016; 80: 1795-1803).
No takes yet. Share an insight, caveat, or question.
Merchant et al. (2016) studied Ventricular non-compaction (n=26). Micro-computed tomography (micro-CT) with iodine staining vs. Wild-type mice / 2D histology was evaluated on Compact myocardium thickness (Right Ventricle) (p=2E-05). Iodine staining-enhanced micro-CT successfully quantified 3D compact myocardial wall thickness, revealing significantly thinner compact myocardium in e12.5 p27-/- knockout mice compared to wild-types.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: