Key result
Retrospectively ECG-gated dual-source CT demonstrated high diagnostic accuracy for differentiating bicuspid from tricuspid aortic valves, with an overall sensitivity of 94% and specificity of 100%.
Why the study?
Does retrospectively ECG-gated dual-source CT accurately differentiate between bicuspid and tricuspid aortic valves compared to echocardiography and surgery?
Observational (n=94)
Blinded observers
Does retrospectively ECG-gated dual-source CT accurately differentiate between bicuspid and tricuspid aortic valves compared to echocardiography and surgery?
Retrospectively ECG-gated dual-source CT is highly accurate for differentiating between bicuspid and tricuspid aortic valves, with systolic reconstructions required for valves with a raphe.
Answers are grounded in this paper and cite their sources.
May support CT for aortic valve differentiation in select cases; leaves open prospective validation before changing practice.
OBJECTIVE: The purpose of this study is to evaluate the diagnostic performance of CT, compared with that of echocardiography and surgery, for differentiating between bicuspid and tricuspid aortic valves. MATERIALS AND METHODS: Forty-seven patients with bicuspid valve and 47 patients with tricuspid aortic valve underwent retrospectively ECG-gated dual-source CT and echocardiography. Thirty-four (72%) of the 47 patients with bicuspid aortic valve underwent valve surgery. Two independent blinded observers assessed the CT image quality of the aortic valve during diastole and systole on a 4-point scale, determined which phase allowed the differentiation of valve type, distinguished between tricuspid and bicuspid aortic valves, and assessed for the presence of a raphe. Diagnostic performance of CT was determined using echocardiography and surgery as the reference standard. RESULTS: According to echocardiography and surgery, seven (15%) of the 47 bicuspid aortic valves had no raphe, and 40 (85%) had a raphe. CT image quality was diagnostic (i.e., scores of 1-3) in all 94 patients in both diastole and systole. Among patients with bicuspid aortic valve and no raphe, differentiation between tricuspid and bicuspid aortic valves could be performed in diastole in 100% (7/7) of cases. Among patients with bicuspid aortic valve and raphe, differentiation was possible only in systole in 5% (2/40) of cases and when combining diastole and systole in 95% (38/40) of cases. In three bicuspid aortic valves with raphe, the valve was misclassified by CT as tricuspid aortic valve. Overall sensitivity and specificity of CT for the diagnosis of bicuspid aortic valve were 94% and 100%. CONCLUSION: CT is highly accurate for differentiation between bicuspid and tricuspid aortic valves. For bicuspid aortic valves without raphe, diastolic reconstructions are sufficient, whereas in those with a raphe, additional reconstructions in systole are required.
No takes yet. Share an insight, caveat, or question.
Alkadhi et al. (2010) conducted an observational in Bicuspid and tricuspid aortic valves (n=94). Retrospectively ECG-gated dual-source CT vs. Echocardiography and surgery was evaluated on Differentiation between bicuspid and tricuspid aortic valves (Sensitivity 94%, Specificity 100%). Retrospectively ECG-gated dual-source CT demonstrated high diagnostic accuracy for differentiating bicuspid from tricuspid aortic valves, with an overall sensitivity of 94% and specificity of 100%.
Synapse has enriched 10 related papers. Consider them for comparative context: