Answers are grounded in this paper and cite their sources.
Mechanical displacement and thermal stress investigation of a two hot arm thermal microactuator (polysilicon type) with different structural and geometrical parameters was investigated in this paper with Comsol Multiphysics software, starting from a validation model based on the real dimensions of a two hot arm thermal microactuator, experimentally tested at different actuation voltages. Variation at different actuation voltages (between 1 and 9 V) for the radiative energy received by the cold arm from the short hot arm and the ratio between the resistive heat energy and radiative energy at different cold arm widths d w with gap between arms g = 2 µm, and respectively at different gap widths g with d w = 15 µm was numerically computed here. Total displacement versus actuation voltages for the actuator models was also evaluated, along with von Mises stress and temperature distributions for identification of maximum bending stress along the inner (short) hot arm of the actuator.
No takes yet. Share an insight, caveat, or question.
Viorel Ionescu (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: