Key result
Pulse pressure variation during forced inspiration accurately predicts fluid responsiveness with ~0.91 AUC.
Why the study?
Does pulse pressure variation during forced inspiratory breathing predict fluid responsiveness in spontaneously breathing patients?
Observational (n=59)
Does pulse pressure variation during forced inspiratory breathing predict fluid responsiveness in spontaneously breathing patients?
Effect estimate: AUC 0.910
Absolute Event Rate: 18.2% vs 10.1%
p-value: p=<0.0001
Pulse pressure variation during forced inspiratory breathing accurately predicts fluid responsiveness in spontaneously breathing patients prior to general anesthesia.
May support pre-anesthesia fluid assessment in spontaneous breathers; leaves open need for randomized validation before practice change.
We evaluated whether pulse pressure variation can predict fluid responsiveness in spontaneously breathing patients. Fifty-nine elective thoracic surgical patients were studied before induction of general anaesthesia. After volume expansion with hydroxyethyl starch 6 ml.kg(-1) , patients were defined as responders by a ≥ 15% increase in the cardiac index. Haemodynamic variables were measured before and after volume expansion and pulse pressure variations were calculated during tidal breathing and during forced inspiratory breathing. Median (IQR [range]) pulse pressure variation during forced inspiratory breathing was significantly higher in responders (n = 29) than in non-responders (n = 30) before volume expansion (18.2 (IQR 14.7-18.2 [9.3-31.3])% vs. 10.1 (IQR 8.3-12.6 [4.8-21.1])%, respectively, p < 0.001). The receiver-operating characteristic curve revealed that pulse pressure variation during forced inspiratory breathing could predict fluid responsiveness (area under the curve 0.910, p < 0.0001). Pulse pressure variation measured during forced inspiratory breathing can be used to guide fluid management in spontaneously breathing patients.
No takes yet. Share an insight, caveat, or question.
Hong et al. (2014) conducted an observational in Elective thoracic surgery (n=59). Pulse pressure variation during forced inspiratory breathing vs. Non-responders was evaluated on Fluid responsiveness (≥ 15% increase in cardiac index after volume expansion) (AUC 0.910, p=<0.0001). Pulse pressure variation during forced inspiratory breathing accurately predicted fluid responsiveness in spontaneously breathing patients (AUC 0.910, P<0.0001).