In this article, we demonstrated the continuous wave (cw) performance of a high-power diode-pumped Nd:GGG laser. The maximum output power of 13.2 W was obtained under the incident pump power of 28.8 W, giving the optical conversion efficiency of 49.5% and the slope efficiency of 51.5%. And the intrinsic loss of Nd:GGG crystal was measured to be 0.86% cm -1 in our experiment.