Key result
An AI model based on fully convolutional networks had higher sensitivity for predicting fetal compromise than clinical practice (0.528 vs 0.132) but a higher false-positive rate (0.632 vs 0.012).
Why the study?
Data-driven analyses show potential for automated electronic fetal monitoring assessment, but the role of a deep learning fully convolutional network model in electronic fetal monitoring evaluation and recognition of nonreassuring fetal status needed evaluation.
Does an AI-based FCN model improve the recognition of EFM traces and prediction of fetal compromise compared to clinical practice in deliveries?
Observational (n=292)
No
Does an AI-based FCN model improve the recognition of EFM traces and prediction of fetal compromise compared to clinical practice in deliveries?
Absolute Event Rate: 0.528% vs 0.132%
An AI-based FCN model demonstrated competitive ability in identifying fetal heart rate patterns with higher sensitivity but lower specificity for predicting fetal compromise compared to physicians.
FCN AI shows moderate physician concordance but trades higher sensitivity for markedly higher false positives in fetal compromise; leaves open clinical adoption pending prospective trials.
BACKGROUND: Cardiotocography is a common method of electronic fetal monitoring (EFM) for fetal well-being. Data-driven analyses have shown potential for automated EFM assessment. For this preliminary study, we used a novel artificial intelligence method based on fully convolutional networks (FCNs), with deep learning for EFM evaluation and correct recognition, and its possible role in evaluation of nonreassuring fetal status. METHODS: We retrospectively collected 3239 EFM labor records from 292 deliveries and neonatal Apgar scores between December 2018 and July 2019 at a single medical center. We analyzed these data using an FCN model and compared the results with clinical practice. RESULTS: The FCN model recognized EFM traces like physicians, with an average Cohen's kappa coefficient of agreement of 0.525 and average area under the receiver operating characteristic curve of 0.892 for six fetal heart rate (FHR) categories. The FCN model showed higher sensitivity for predicting fetal compromise (0.528 vs 0.132) but a higher false-positive rate (0.632 vs 0.012) compared with clinical practice. CONCLUSION: FCN is a modern technique that may be useful for EFM trace recognition based on its multiconvolutional layered analysis. Our model showed a competitive ability to identify FHR patterns and the potential for evaluation of nonreassuring fetal status.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2020) conducted an observational in Fetal well-being / intrapartum cardiotocography (n=292). Artificial intelligence method based on fully convolutional networks (FCNs) vs. Clinical practice (physicians) was evaluated on Sensitivity for predicting fetal compromise. An AI model based on fully convolutional networks had higher sensitivity for predicting fetal compromise than clinical practice (0.528 vs 0.132) but a higher false-positive rate (0.632 vs 0.012).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: