Key result
Sub-band coding achieves a ~5.7 compression ratio for ECG data without visual distortion.
Answers are grounded in this paper and cite their sources.
A sub-band coding technique for ECG data compression achieves compression ratios up to 5.7 without visual distortion.
A data compression technique is presented for discrete-time electrocardiogram signals. The single lead electrocardiogram signal is decomposed into several multiresolution subsignals by using a quadrature mirror filter bank. The resultant subsignals are compressed according to their frequency contents using various coding methods, including a discrete cosine transform based technique and pulse code modulation with variable length coding. Compression ratios as high as 5.7 are obtained without introducing any visual distortion.
No takes yet. Share an insight, caveat, or question.
Aydin et al. (1991) studied Electrocardiogram signals. Sub-band coding using quadrature mirror filter bank and various coding methods was evaluated on Compression ratio and visual distortion. A sub-band coding technique for ECG data compression achieved compression ratios as high as 5.7 without introducing any visual distortion.
Synapse has enriched 10 related papers. Consider them for comparative context: