Answers are grounded in this paper and cite their sources.
When a composite resin restoration is photopolymerized, a considerable amount of heat can be produced, potentially causing pulpal injury.Objective: Evaluate the influence of the type of light source and remaining dentin thickness on the temperature increase in the pulp chamber while curing composite resin restorations.Material and Methods: Ninety-six tooth fragments obtained from bovine incisors were divided into groups/ subgroups (n=12), according to the light source (LED and halogen light) and remaining dentin thickness (3.5, 3, 2, and 1mm).Class I cavities were prepared and restored with a composite resin.A temperature increase was obtained during photopolymerization of the adhesive and each composite increment.Data were analyzed using ANOVA and Fisher's Test (α=5%).Results: LED promoted higher temperature increments when compared with the halogen light.Temperature levels were the lowest for 3.5mm-thick and the highest for 1mm-thick remaining dentin.Levels registered during the photopolymerization of each composite increment were superior for LED.Conclusions: Both light sources result in temperature increases above 5.5°C.Additionally, the remaining dentin thickness of 1mm promoted the largest temperature increase.
No takes yet. Share an insight, caveat, or question.
Savaris et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: