Key result
Increasing intracellular proton concentration reduces BK channel currents by ~53% via competitive inhibition with potassium.
Protons block BK channels via cooperative competitive inhibition with intracellular potassium, which contributes to the limits of unitary currents at high voltages.
May inhibit BK currents in acidic microenvironments; leaves open relevance to cardiac excitability in vivo.
Proton block of unitary currents through BK channels was investigated with single-channel recording. Increasing intracellular proton concentration decreased unitary current amplitudes with an apparent pKa of 5.1 without discrete blocking events, indicating fast proton block. Unitary currents recorded at pH(i) 8.0 and 9.0 had the same amplitudes, indicating that 10(-8) M H(+) had little blocking effect. Increasing H(+) by recording at pH(i) 7.0, 6.0, and 5.0 then reduced the unitary currents by 13%, 25%, and 53%, respectively, at +200 mV. Increasing K(+)(i) relieved the proton block in a manner consistent with competitive inhibition of K(+)(i) action by H(+)(i). Proton block was voltage dependent, increasing with depolarization, indicating that block was coupled to the electric field of the membrane. Proton block was not described by the Woodhull equation for noncompetitive voltage-dependent block, but was described by an equation for cooperative competitive inhibition that included voltage-dependent block from the Woodhull equation. Proton block was still present after replacing the eight negative charges in the ring of charge at the entrance to the intracellular vestibule by uncharged amino acids. Thus, the ring of charge is not the site of proton block or of competitive inhibition of K(+)(i) action by H(+)(i). With 150 mM symmetrical KCl, unitary current amplitudes increased with depolarization, reaching 66 pA at +350 mV (pH(i) 7.0). The increase in amplitude with voltage became sublinear for voltages >100 mV. The sublinearity was unaffected by removing from the intracellular solutions Ca(2+) and Ba(2+) ions, the Ca(2+) buffers EGTA and HEDTA, the pH buffer TES, or by replacing Cl(-) with MeSO(3)(-). Proton block accounted for approximately 40% of the sublinearity at +200 mV and pH 7.0, indicating that factors in addition to proton block contribute to the sublinearity of the unitary currents through BK channels.
No takes yet. Share an insight, caveat, or question.
Brelidze et al. (2004) studied this question. Intracellular proton concentration vs. pH(i) 8.0 and 9.0 was evaluated on Unitary current amplitudes. Increasing intracellular proton concentration decreased unitary current amplitudes through BK channels by up to 53% at pH 5.0 (+200 mV) via competitive inhibition with intracellular potassium.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: