Answers are grounded in this paper and cite their sources.
OBJECTIVE: The inter-frequency amplitude ratio (IFAR) is the ratio of the amplitude of 1000-Hz tone-burst evoked ocular vestibular evoked myogenic potential (oVEMP) to the 500 Hz tone-burst evoked oVEMP. Since IFAR is an amplitude-based parameter, and the amplitudes of oVEMP for different frequencies are differentially affected by ageing, IFAR could potentially be affected by the ageing process. Therefore, we aimed to examine the effects of ageing on the IFAR of oVEMPs. DESIGN: Multiple static groups comparison. STUDY SAMPLE: We recorded oVEMPs for 500 Hz and 1000 Hz tone-bursts from 270 healthy individuals, each included in one of the six age groups. CONCLUSIONS: IFAR, a sensitive tool in the test battery for the diagnosis of Meniere's disease, is affected even in healthy individuals due to ageing; hence its cautious interpretation is recommended when evaluating adults >50 years of age who are suspected of having Meniere's disease.
No takes yet. Share an insight, caveat, or question.
Singh et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: