Answers are grounded in this paper and cite their sources.
A short-term follow-up study was performed on 55 workers in a gear plant exposed to PCB that contaminated the work surfaces. Current work did not involve the use of PCBs. Exposure was to residual PCB left behind by a capacitor company which formerly used the site. Elevated PCB levels were found in production area workers; these elevations persisted on retesting 1 year later. Efforts should be made to identify potentially toxic materials left behind on work surfaces of buildings before remodeling or reuse.
No takes yet. Share an insight, caveat, or question.
Christiani et al. (1986) studied this question.