Key result
In ventilated patients with normal lungs, positive end-expiratory pressure ≥8 cmH2O increased pulse pressure variation compared to 2 cmH2O.
Why the study?
Does the level of positive end-expiratory pressure (PEEP) affect pulse pressure variation (PPV) in ventilated patients?
Observational
No
Does the level of positive end-expiratory pressure (PEEP) affect pulse pressure variation (PPV) in ventilated patients?
Answers are grounded in this paper and cite their sources.
In ventilated patients with normal lungs, PEEP levels ≥ 8 cmH2O significantly overestimate pulse pressure variation, suggesting measurements should be standardized at PEEP ≤ 5 cmH2O.
Objectives: To determine the effect of different levels of positive end-expiratory pressure (PEEP) on pulse pressure variation (PPV).Design: An observational study.Setting: Operating theatres of a tertiary training hospital.Subjects: Ventilated patients who required intra-arterial blood pressure monitoring.Outcome measures: PPV during different levels of PEEP.Method: Patients were anaesthetised by means of a standard technique and ventilated with a tidal volume of 9 ml/kg ideal body mass. The PPV was calculated at PEEP levels of 2, 5, 8 and 10 cmH2O. PPV was compared at the various PEEP levels.Results: PPV at a PEEP of 8 cmH2O and 10 cmH2O was significantly larger than that at 2 cmH2O (p-value < 0.001). PPV at a PEEP of 10 cmH2O was significantly larger than that at 8 cmH2O (p-value < 0.001). PPV at a PEEP of 8 cmH2O was larger than that at 5 cmH2O (p-value = 0.002). PPV at a PEEP of 2 and 5 cmH2O did not differ significantly (p-value = 0.194).Conclusion: We have demonstrated that, in patients with normal lungs, PEEP has a significant influence on PPV. PPV may be overestimated if PEEP ≥ 8 cmH2O is applied in patients who are ventilated with a tidal volume of 9 ml/kg. It is recommended that in patients with healthy lungs PPV should be measured at a standardised PEEP of ≤ 5 cmH2O.
No takes yet. Share an insight, caveat, or question.
Smith et al. (2012) conducted an observational in Ventilated patients requiring intra-arterial blood pressure monitoring. Positive end-expiratory pressure (PEEP) vs. Lower levels of PEEP (e.g., 2 cmH2O or 5 cmH2O) was evaluated on Pulse pressure variation (PPV) (p=<0.001). In ventilated patients with normal lungs, positive end-expiratory pressure ≥8 cmH2O increased pulse pressure variation compared to 2 cmH2O.
Synapse has enriched 10 related papers. Consider them for comparative context: