Key result
Cook detachable coil optimizes PDA closure cost-effectiveness at ~$11/YOL, though Nit Occlud yields fewer complications.
Why the study?
Does the choice of device (ADO II, Cook detachable coil, NOC) affect cost and effectiveness in pediatric patients undergoing closure of small-to-medium-sized PDA?
Observational (n=116)
No
Does the choice of device (ADO II, Cook detachable coil, NOC) affect cost and effectiveness in pediatric patients undergoing closure of small-to-medium-sized PDA?
In pediatric patients with small-to-medium PDAs, the Cook detachable coil is the most cost-effective closure device, whereas the Nit Occlud coil offers higher effectiveness and fewer complications.
Answers are grounded in this paper and cite their sources.
Supports weighing cost in pediatric PDA device choice; leaves open need for RCTs to confirm optimal selection.
Aims: In this study, we examined the differences in cost and effectiveness of various devices used for the closure of small to medium sized patent ductus arteriosus (PDA). Setting and Design: We retrospectively studied 116 patients who underwent closure of small PDAs between January 2010 and January 2015. Subjects and Methods: Three types of devices were used: the Amplatzer duct occluder (ADO) II, the cook detachable coil and the Nit Occlud coil (NOC). Immediate and late complications were recorded and patients were followed up for 3 months after the procedure. Statistical Methods: All statistical calculations were performed using Statistical Package for the Social Science software. P <0.05 were considered significant. Results: We successfully deployed ADO II devices in 33 out of 35 cases, cook detachable coils in 36 out of 40 cases and NOCs in 38 out of 41 cases. In the remaining nine cases, the first device was unsuitable or embolized and required retrieval and replacement with another device. Eleven patients (9.5%) developed vascular complications and required anticoagulation therapy. Patients who had hemolysis or vascular complications remained longer in the intensive care unit, with consequently higher total cost (P = 0.016). Also, the need for a second device increased the cost per patient. Conclusions: The cook detachable coil is the most cost-effective device for closure of small-to medium-sized PDAs. Calculations of the incremental cost-effectiveness. (ICE) revealed that the Cook detachable coil had less ICE than the ADO II and NOC. The NOC was more effective with fewer complications.
No takes yet. Share an insight, caveat, or question.
Mandour et al. (2017) conducted an observational in small-to-medium-sized patent ductus arteriosus (n=116). Cook detachable coil vs. Amplatzer duct occluder (ADO) II and Nit Occlud coil (NOC) was evaluated on Cost-effectiveness ratio ($/YOL) (p=<0.05). The Cook detachable coil was the most cost-effective device for PDA closure with a mean ratio of $11.3/YOL, though the Nit Occlud coil was more effective with fewer complications.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: