Key result
Greater aortic plaque thickness linked to acute stroke within 48 hours post-TAVR.
Why the study?
Little information is available on computed tomography-based predictors of stroke related to transcatheter aortic valve replacement.
Does aortic wall plaque thickness measured by preprocedural CT predict acute stroke within 48 hours after TAVR in patients with severe aortic stenosis?
Case-Control (n=1,270)
Does aortic wall plaque thickness measured by preprocedural CT predict acute stroke within 48 hours after TAVR in patients with severe aortic stenosis?
p-value: p=<.01
Aortic wall plaque thickness measured by preprocedural contrast-enhanced CT may serve as a predictive parameter for acute stroke within 48 hours after TAVR.
Aortic plaque thickness on pre-TAVR CT may flag early stroke risk but should not yet change practice; leaves open prospective validation for risk stratification.
OBJECTIVES: Little information is available on computed tomography (CT)-based predictors of stroke related to transcatheter aortic valve replacement (TAVR). The objective of this study was to determine whether anatomical features of the aortic valve and aorta visualized by CT are predictive parameters of stroke. METHODS: The study included 1270 patients who underwent preprocedural contrast-enhanced CT assessment and TAVR for severe aortic valve stenosis. Twenty-six patients (2.5%) who developed acute strokes that occurred within 48 hours after TAVR and 104 matched patients without strokes were identified, using 1:4 propensity-score matching. The degree of hypoattenuation in the aortic valve leaflets, calcium volume of the aortic valve, and plaque thickness in the aortic wall (the ascending aorta, aortic arch, and descending thoracic aorta) were assessed. RESULTS: There were no differences between the two groups in the degree of hypoattenuation in the aortic valve leaflets and calcium volume of the aortic valve. The plaque thickness of the aortic arch and descending aorta were greater in the stroke group than in the non-stroke group: aortic arch, 2.4 mm (IQR, 1.3-2.8 mm) vs 1.8 mm (IQR, 1.4-2.2 mm), respectively (P<.01); and descending aorta, 2.9 mm (IQR, 2.1-4.2 mm) vs 2.8 mm (IQR, 2.1-3.6 mm); respectively (P=.049). CONCLUSION: Aortic wall plaque thickness measured by contrast-enhanced CT might be a predictive parameter of strokes that occur within 48 hours after TAVR.
No takes yet. Share an insight, caveat, or question.
Miyasaka et al. (2020) conducted a case-control in Severe aortic valve stenosis (n=1,270). Aortic wall plaque thickness vs. Matched patients without stroke was evaluated on Acute stroke within 48 hours after TAVR (p=<.01). Greater aortic arch (2.4 vs 1.8 mm, P<0.01) and descending aorta (2.9 vs 2.8 mm, P=0.049) plaque thickness was associated with acute stroke within 48 hours after TAVR.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: