Engineering assessment reveals reduced energy use and improved textile quality in an industrial laundry, indicating major sustainability and efficiency gains.
The study assessed changes in energy, temporal, technological, environmental, and washing-quality parameters after introducing a central heat recovery system in an industrial laundry. Instrumental measurements, gravimetric and microbiological methods, textile mechanical testing, and calculations of energy-efficiency and carbon dioxide (CO2)-emission indicators were applied. Specific heat energy consumption decreased from 7.8 to 4.6 kWh/kg, while heat energy use for 100 t of laundry fell from 780 to 460 MWh. Recovered heat supplied 42% of the total heat demand, reducing steam-boiler load from 100% to 72% and shortening the washing cycle from 35 to 30 min. Washing-tunnel performance increased from 1000 to 1200 kg/h, and completed cycles per shift increased from 13 to 16. Annual natural gas consumption decreased from 430 to 300 thousand m³, and specific carbon dioxide emissions from 62 to 42 kg/t. Average moisture after drying declined from 6.5% to 4.8%, while laundry ready for folding increased from 78% to 92%. Protein- and fat-contaminant removal and whiteness also improved. A separate ozonation test increased microbial reduction but was not attributed to heat recovery. The integral energy efficiency index increased from 1.00 to 2.03.
No takes yet. Share an insight, caveat, or question.
Jakub Steller (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: