Key result
Intracoronary Probing Catheter technique achieves successful dilatation in ~67% of CTOs.
Why the study?
PTCA of total coronary occlusion is limited by the inability of guidewires and conventional dilating catheters to cross all such lesions.
Does the use of an intracoronary probing catheter and ultralow profile balloon-on-a-wire probe allow for successful dilatation in patients with chronic total coronary occlusions?
Observational (n=13)
Does the use of an intracoronary probing catheter and ultralow profile balloon-on-a-wire probe allow for successful dilatation in patients with chronic total coronary occlusions?
The intracoronary probing catheter technique offers a promising method for successful dilatation of chronic total coronary occlusions, including in cases where conventional systems fail.
Answers are grounded in this paper and cite their sources.
Intracoronary probing catheter may enable CTO dilatation after failed attempts; leaves open comparative effectiveness versus modern techniques.
Coronary angioplasty (PTCA) of total coronary occlusion is limited by the inability of guidewires and conventional dilating catheters to cross all such lesions. We have therefore developed a technique for PTCA of chronic total coronary occlusions using the ultralow profile "balloon-on-a-wire" Probe. An intracoronary Probing Catheter is used to facilitate crossing the stenosis with a guidewire and then to deliver a Probe into the obstruction for balloon dilatation. This technique was used in 13 patients including six in whom other dilating systems had failed to cross the occlusion. Successful dilatation was performed in nine patients (67%). Among the six patients in whom other dilating systems had failed, dilatation was performed in five using the Probing Catheter technique with a successful outcome achieved in four (67%). The Probing Catheter technique offers a promising new method to apply "balloon-on-a-wire" technology to the dilatation of chronic total coronary occlusions. This method may allow successful dilatation when other dilating systems fail.
No takes yet. Share an insight, caveat, or question.
Little et al. (1989) conducted an observational in Chronic total coronary occlusions (n=13). Intracoronary Probing Catheter technique was evaluated on Successful dilatation. The intracoronary Probing Catheter technique achieved successful dilatation in 67% (9 of 13) of patients with chronic total coronary occlusions, including 4 of 6 where other systems had failed.
Synapse has enriched 10 related papers. Consider them for comparative context: