Key result
Sequential EEG and SSEP monitoring detects severe cerebral ischemia in ~2% of carotid endarterectomies.
Why the study?
Does sequential EEG and SSEP monitoring accurately identify severe cerebral ischemia during carotid endarterectomy?
Observational (n=255)
Does sequential EEG and SSEP monitoring accurately identify severe cerebral ischemia during carotid endarterectomy?
Sequential use of EEG and SSEPs during carotid endarterectomy provides complementary monitoring, as SSEPs can detect slow-onset cerebral ischemia missed by EEG.
Answers are grounded in this paper and cite their sources.
May support sequential EEG-SSEP monitoring to detect missed ischemia in carotid endarterectomy; leaves open impact on perioperative outcomes.
Selective shunt during carotid endarterectomy is more and more widespread, but it requires a monitoring system able to identify severe brain ischemia correctly. In 255 endarterectomies for severe carotid stenosis, we evaluated cerebral activity by means of sequential use of computerized two-channel electroencephalogram (EEG) and somatosensory evoked potentials (SSEPs). In 1.96% of cases, we observed changes referable to severe cerebral ischemia: in one case, in spite of shunting, EEG asymmetry persisted till the end of the operation, and the patient awoke with irreversible aphasia. In two other cases, a progressive disappearance of the cortical wave (N20) occurred in spite of a normal EEG pattern. None of the unshunted patients had postoperative deficit. Computerized EEG is an easily interpretable method of monitoring and reveals rapidly developing cerebral ischemia, but severe SSEP changes can occur in spite of a normal EEG pattern when cerebral ischemia has a slow onset. Although SSEP monitoring is a slower method of recording, it can give a finer distinction of less severe cerebral ischemia.
No takes yet. Share an insight, caveat, or question.
Fiori et al. (1995) conducted an observational in Severe carotid stenosis (n=255). Sequential computerized two-channel EEG and SSEPs was evaluated on Changes referable to severe cerebral ischemia. Sequential monitoring with EEG and SSEPs during carotid endarterectomy detected severe cerebral ischemia in 1.96% of cases, with SSEPs identifying slow-onset ischemia despite a normal EEG pattern.
Synapse has enriched 10 related papers. Consider them for comparative context: