Answers are grounded in this paper and cite their sources.
The increasing demand of in-situ and operando experiments require working distances in X-ray microscopes of at least several millimeters and up to several centimeters. This space becomes necessary to contain the experimental setup, stages and chambers as well as the samples. We have developed a monolithic 2D focusing MLL optics based on two crossed MLLs with low stress multilayers of the Mo/C/Si/C system [3, 4]. This multilayer configuration allows to deposit multilayer stacks with a total thicknesses of up to 100 μm. With this large aperture we designed an MLL with an extraordinary long focal length and a corresponding long working distance of several centimeters and diffraction limited focal spot sizes well below 100 nm. A measurement with an MLL based on this multilayer system has demonstrated the capability to realize high diffraction efficiencies close to theoretical predictions [5].
No takes yet. Share an insight, caveat, or question.
Kubec et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: