Key result
Failed tracheal intubation occurs in ~3 per 1000 obstetric general anaesthesia cases.
The incidence of failed tracheal intubation in obstetric general anaesthesia has remained unchanged since 1970, carrying significant risks of maternal mortality and morbidity.
Answers are grounded in this paper and cite their sources.
Obstetric GA still carries failed intubation risk requiring preparedness; leaves open whether modern techniques can reduce the stable incidence.
We reviewed the literature on obstetric failed tracheal intubation from 1970 onwards. The incidence remained unchanged over the period at 2.6 (95% CI 2.0 to 3.2) per 1000 anaesthetics (1 in 390) for obstetric general anaesthesia and 2.3 (95% CI 1.7 to 2.9) per 1000 general anaesthetics (1 in 443) for caesarean section. Maternal mortality from failed intubation was 2.3 (95% CI 0.3 to 8.2) per 100000 general anaesthetics for caesarean section (one death per 90 failed intubations). Maternal deaths occurred from aspiration or hypoxaemia secondary to airway obstruction or oesophageal intubation. There were 3.4 (95% CI 0.7 to 9.9) front-of-neck airway access procedures (surgical airway) per 100000 general anaesthetics for caesarean section (one procedure per 60 failed intubations), usually carried out as a late rescue attempt with poor maternal outcomes. Before the late 1990s, most cases were awakened after failed intubation; since the late 1990s, general anaesthesia has been continued in the majority of cases. When general anaesthesia was continued, a laryngeal mask was usually used but with a trend towards use of a second-generation supraglottic airway device. A prospective study of obstetric general anaesthesia found that transient maternal hypoxaemia occurred in over two-thirds of cases of failed intubation, usually without sequelae. Pulmonary aspiration occurred in 8% but the rate of maternal intensive care unit admission after failed intubation was the same as that after uneventful general anaesthesia. Poor neonatal outcomes were often associated with preoperative fetal compromise, although failed intubation and lowest maternal oxygen saturation were independent predictors of neonatal intensive care unit admission.
No takes yet. Share an insight, caveat, or question.
Kinsella et al. (2015) conducted a review in Obstetric failed tracheal intubation. Obstetric general anaesthesia was evaluated on Incidence of failed tracheal intubation per 1000 obstetric general anaesthetics (95% CI 2.0 to 3.2). The incidence of failed tracheal intubation during obstetric general anaesthesia was 2.6 per 1000 anaesthetics, with a maternal mortality rate of 2.3 per 100,000.
Synapse has enriched 10 related papers. Consider them for comparative context: