Key result
Ductus arteriosus Doppler flow indicates pulmonary artery pressure, but Bernoulli-derived trough measurements are unreliable.
Why the study?
Can Doppler ultrasound flow characteristics accurately assess pulmonary artery pressure in patients with ductus arteriosus?
Observational (n=117)
Can Doppler ultrasound flow characteristics accurately assess pulmonary artery pressure in patients with ductus arteriosus?
Doppler ultrasound flow patterns provide a qualitative indication of pulmonary artery pressure in ductus arteriosus, but quantitative estimation using the Bernoulli equation is not yet reliable.
Qualitative Doppler patterns may inform pulmonary pressures in ductus arteriosus; leaves open reliable Bernoulli quantification pending validation.
The Doppler spectral pattern of flow through the ductus arteriosus was studied in 117 patients. In 37 who underwent catheterisation, Doppler records and aortic and pulmonary artery pressure were available (21 simultaneously with two catheters) for review while the others had surgical ligation of the duct on the basis of the results of non-invasive tests. Four flow patterns were obtained: (a) continuous flow, maximum velocity in late systole with gradual fall throughout diastole; (b) continuous flow, high systolic flow with rapid fall to a very low early diastolic velocity maintained throughout diastole; (c) continuous low velocity, maximum in late diastole; and (d) bidirectional flow. Flow pattern (a) was associated with normal or slightly raised pulmonary artery pressure; (b) with raised pulmonary artery pressure; and (c) and (d) with pulmonary artery pressure at systemic values. Comparison of the Doppler and measured pressure differences between the great arteries was reasonably good for peak values but poor for the trough readings. Doppler ultrasound clearly showed ductal flow; the flow pattern gave an indication of the pulmonary artery pressure, but pressure measurement by application of the Bernoulli equation to the flow velocities cannot yet be regarded as reliable.
No takes yet. Share an insight, caveat, or question.
Houston et al. (1989) conducted an observational in Ductus arteriosus (n=117). Doppler ultrasound vs. Invasive catheterization was evaluated on Pulmonary artery pressure and pressure differences between great arteries. Doppler ultrasound flow patterns in ductus arteriosus indicated pulmonary artery pressure, but Bernoulli equation-derived pressure measurements were unreliable for trough readings.