Key result
Transradial BACTRA technique enables 100% successful aortic valve crossing and deployment without extra arterial access.
Why the study?
Crossing the aortic valve during TAVI can be challenging, and conventional balloon-assisted crossing typically requires a second large femoral access.
Does the BACTRA technique improve valve crossing success in patients undergoing TAVI with difficult anatomy?
Case Report (n=2)
No
Does the BACTRA technique improve valve crossing success in patients undergoing TAVI with difficult anatomy?
The BACTRA technique provides a safe and effective alternative for difficult aortic valve crossing during TAVI, avoiding the need for secondary femoral access.
May facilitate difficult TAVI crossings via transradial access without extra punctures; hypothesis-generating and requires prospective validation.
Background: Crossing the aortic valve with the device during transcatheter aortic valve implantation (TAVI) can be challenging, with several troubleshooting techniques described. Balloon-assisted valve crossing is commonly considered, although the need for a second femoral access of sufficient size to accommodate the valvuloplasty balloon limits its appeal. Case summary: -radial access. Where difficulty was encountered with crossing the valve and basic techniques were unsuccessful, the BACTRA (Balloon-Assisted Crossing via Trans-Radial Access) technique facilitated valve crossing and successful valve deployment. In Case 1, the inability to cross the valve related predominantly to severe tortuosity throughout the arterial tree and a subsequent lack of torque and device manipulation to negotiate the native valve. In Case 2, the issue largely related to the horizontal aorta. Both patients had successful valve deployment and were subsequently discharged well. Discussion: Regardless of the underlying cause or the TAVI platform utilized, this report demonstrates that the BACTRA technique has several plausible benefits. Valve crossing was facilitated in both cases without additional arterial punctures or sheath upsizing, allowing the procedures to proceed efficiently and safely without any added risk of vascular complications. Procedural steps, troubleshooting, and equipment compatibility are outlined in this case series.
No takes yet. Share an insight, caveat, or question.
Hamilton et al. (2026) conducted a case report in Severe aortic stenosis with difficult valve crossing during TAVI (n=2). BACTRA (Balloon-Assisted Crossing via Trans-Radial Access) technique was evaluated on Successful valve crossing and deployment. The BACTRA technique facilitated successful aortic valve crossing and deployment without additional arterial punctures or vascular complications in two cases.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: