This is the authors' abstract. We don't add key points for this paper.
The pharmaceutical industry is moving from off-line to real-time release testing (RTRT) to enhance quality while reducing costs. UV/Vis spectroscopy has emerged as a promising tool for RTRT given its simplicity, sensitivity and cost-effectiveness. Nevertheless, the effective sample size must be characterized in relation to the penetration depth to justify its representativeness and suitability for RTRT. In this study, bilayer tablets were produced using a hydraulic tablet press. The lower layer contained titanium dioxide and microcrystalline cellulose (MCC), while the upper layer consisted of MCC, lactose or a combination with theophylline. The thickness of the upper layer was stepwise increased. Spectra from 224 to 820 nm were recorded with an orthogonally aligned UV/Vis probe. Thereby, the experimental penetration depth reached up to 0.4 mm, while the Kubelka-Munk model yielded a theoretical maximum penetration depth of 1.38 mm. Based on these values, the effective sample sizes were determined. Considering a parabolic penetration profile, the maximum volume was 2.01 mm³. The results indicated a wavelength and particle size dependency. Micro-CT analysis confirmed the even distribution of the API in the tablets proving the sufficiency of the UV/Vis sample size. Consequently, UV/Vis spectroscopy is a reliable alternative for RTRT in tableting.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Brands et al. (2025) studied this question.