Key result
Permanent pacemaker implantation carries up to ~6% complication risk, most commonly hematoma and lead dislodgement.
Answers are grounded in this paper and cite their sources.
Permanent pacemaker implantation carries a 1% to 6% risk of complications, including hematoma, lead dislodgement, infection, perforation, and dysrhythmias, necessitating vigilant monitoring.
Cardiologists have used implanted cardiac pacemakers to treat symptomatic bradydysrhythmias for approximately 60 years.1 Pacemakers provide an artificial electrical stimulus to initiate a cardiac cycle. Indications for permanent pacemaker implantation include sinus node dysfunction with documented symptomatic bradycardia, symptomatic chronotropic incompetence, and symptomatic sinus bradycardia that results from required drug therapy for medical disorders.1,2 (See Transvenous permanent dual-chamber pacemaker.) The risk of complications exists with any invasive procedure. Overall, complications occur in 1% to 6% of all pacemaker implantation procedures.3 Complications can range from superficial bleeding to fatal infections or cardiac arrest.3 This article provides an overview of five common complications associated with permanent pacemaker implantation using a transvenous lead system: hematoma, lead dislodgement, infection, lead perforation, and dysrhythmias. Hematoma Of the various pacemaker complications, generator pocket hematoma is the most common, accounting for over 3% of pacemaker complications.1 Hematoma treatment includes surgical evacuation, interruption of previously prescribed anticoagulants, extended hospital stay for monitoring, and possible transfusion.3 According to a retrospective study of over 78,000 patients enrolled in the Nationwide Inpatient Sample database, 2.1% developed a postprocedural hematoma after primary pacemaker implantation. The study also noted that the likelihood of developing a hematoma increases in patients over age 75 and in patients with comorbid heart failure, coagulopathy, or renal failure. The study also examined mortalities and financial costs associated with hematomas. The authors noted in-hospital mortality was slightly higher (1.3%), and associated hospitalization costs increased by over $14,000 in patients who developed a hematoma.4 In patients receiving anticoagulation, the incidence of hematoma increased. In the Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial (BRUISE CONTROL) study, 668 patients undergoing pacemaker or implantable cardiac defibrillator (ICD) placement were randomized to either continue warfarin or heparin bridging. The primary endpoint was hematoma development requiring intervention or prolonged hospital stay. Patients who received heparin bridging were over four times more likely (16%) to develop a hematoma than patients who remained on warfarin (3.5%).5 The Implantable Cardiac Pulse Generator Replacement (REPLACE) Registry studied the complication rates of more than 1,700 patients undergoing pacemaker or ICD generator replacement and/or upgrade. In the patients undergoing generator replacement alone, 0.7% (n=7) experienced hematoma requiring intervention. Of those, six patients were receiving long-term anticoagulant or antiplatelet therapy. In the cohort of patients receiving generator and lead upgrade, 1.5% (n=11) experienced a hematoma that required intervention. Of those, seven patients were on long-term anticoagulant or antiplatelet medications. Lead dislodgement requiring intervention Because a pacemaker lead wire must be in physical contact with the endocardium, lead dislodgement is a common cause of failure to capture and failure to sense. According to the REPLACE Registry, lead dislodgement requiring replacement of one or more lead wires is the most common complication of pacemaker generator or lead upgrade.3 Lead dislodgement typically occurs within the first 3 months after implantation.6 Patients over age 75 were twice as likely to develop lead dislodgement than their younger counterparts.7 Ratchet-traction effect results in lead dislodgement due to loosely tied sutures, allowing the lead wire to move freely with arm movement. The lead wire is pulled with arm extension and is looped back around the generator when the arm is returned to a neutral position. Over time, the patient can develop muscle twitching around the malpositioned lead wire or syncope due to failed pacing.8 Twiddler's syndrome is another cause of lead dislodgement, resulting from twisting or rotating the generator within the subcutaneous pocket.9 Patients may unintentionally or deliberately manipulate the pacemaker generator within its pocket. By rotating the generator, the lead wires can become coiled and dislocated from the heart. Twiddler's syndrome is more often reported among older adult females with impaired cognition.10 Reel syndrome is a variation of Twiddler's syndrome, in which the generator is rotated on the transverse axis in the pocket.11 Lead dislodgement usually requires replacement of the lead wires and/or securement of the pacemaker generator within the pocket.8 Infection Any invasive procedure leads to a risk of infection. Pacemaker infections can occur in the generator pocket, along the lead wires, the heart valves, and the endocardium.1 The incidence of infection can be as high as 5% of patients receiving a permanent pacemaker or generator replacement; three-quarters of infections occur within the first year after implantation.1 Increased infection risk is associated with comorbidities such as diabetes, end-stage renal disease, heart failure, steroid use, lack of antibiotic prophylaxis, chronic obstructive pulmonary disease, history of device infection, hematoma at the insertion site, use of temporary cardiac pacing, intervention for lead dislodgement, and device replacement.12Figure: Transvenous permanent dual-chamber pacemakerGenerator pocket infection signs and symptoms include erythema, pain, edema, warmth, purulent drainage, or nonhealing incision. A common source of pocket infection is procedural contamination with Staphylococcus aureus and coagulase-negative staphylococci.13 An infected pocket can also lead to the generator eroding through the skin. Current American Heart Association guidelines recommend 10 to 14 days of targeted antibiotic therapy and device removal for pocket infections with negative blood cultures.13 Deep infection, such as infection along the lead wires or endocarditis, may be characterized by fever, chills, and pain at the site.1 In patients with positive blood cultures, transesophageal echocardiography (TEE) is recommended to identify vegetations or other signs of endocarditis or myocardial abscess.13 Like pocket infections, deep infections also require device removal and antibiotic therapy for as long as 6 weeks.13 Device replacement timing is based on TEE results and the presence of vegetation either on the lead or valve. Current guidelines recommend waiting 14 days after negative blood culture following device removal for valve vegetation, and 72 hours after negative blood culture following device removal for lead vegetation.12 In addition, it is recommended that a replacement device be implanted in an alternate location from the initial site.12 Lead perforation Lead perforation is relatively rare, accounting for up to 0.8% of pacemaker complications.14 Perforation can lead to pericardial effusion, pneumothorax, hemothorax, or even death.14 Risk factors for perforation include female gender, steroid administration, and advanced age.14 Signs and symptoms include chest pain, fatigue, fever, pleural effusion, and cardiac tamponade.1 Because vague symptoms can be mistaken for other disorders, such as musculoskeletal problems or infection, treatment can be delayed until the patient's clinical status worsens and the patient returns to the ED. Acute lead perforations occur less than 1 month after implantation, and can be fatal in up to 1% of patients.14 Diagnosis can be easily made via computed tomography showing the lead malposition. Treatment involves repositioning or replacement of the lead wire, treatment of pleural effusion and other complications if necessary, and thorough follow-up care to detect subsequent problems. Hemothorax or pneumothorax may require chest tube placement. Dysrhythmias Ventricular dysrhythmias can occur when the pacemaker doesn't sense an intrinsic QRS complex, including premature ventricular contractions.15 If the pacemaker does not sense intrinsic ventricular contractions, it may deliver an impulse inappropriately, which can induce ventricular tachycardia or ventricular fibrillation. Automatic capture algorithms create a blockout period to detect spontaneous activity and adjust the pacemaker's impulse output to allow the pacemaker to confirm capture after an evoked response. These automatic capture algorithms reduce the pacemaker's output and prolong generator longevity, especially in patients with high-pacing thresholds.15 Undersensing can be corrected by adjusting the sensitivity or automatic capture feature of the pacemaker.16 Conclusion The complications outlined here are the most common ones associated with permanent pacemaker implantation. Other less common complications include increased scar formation at the generator pocket site, chronic pain, thromboembolism, and stroke.1 In the United States, there are more than 250,000 pacemakers implanted annually with a low incidence of complications.17 However, hematoma, lead dislodgement, infection, lead perforation, and dysrhythmias can all be life threatening. Using best practices regarding care of the surgical site and providing patient education regarding care of the insertion site can go a long way toward preventing infections. Vigilant monitoring and early detection of complications may prevent a relatively common procedure from becoming catastophic.
No takes yet. Share an insight, caveat, or question.
Terri Townsend (2018) conducted a review in Permanent cardiac pacemaker complications. Permanent pacemaker implantation was evaluated. Permanent pacemaker implantation is associated with an overall complication rate of 1% to 6%, most commonly including hematoma, lead dislodgement, infection, lead perforation, and dysrhythmias.
Synapse has enriched 10 related papers. Consider them for comparative context: