Answers are grounded in this paper and cite their sources.
Background: The precision of marginal adaptation and internal fit plays a critical role in the longevity and clinical success of zirconia crowns. Computer-aided design and computer-aided manufacturing (CAD/CAM) systems have revolutionized dental prosthesis fabrication, yet discrepancies exist in their accuracy. Methods: A total of 60 zirconia crowns were fabricated on identical typodont molar preparations using three CAD/CAM workflows ( n = 20 per group). Marginal adaptation and internal fit were measured using the silicone replica technique under a stereomicroscope. Descriptive statistics were calculated, and comparisons were made using one-way ANOVA followed by post-hoc Tukey test (α = 0.05). Results: The mean marginal gap was smallest in the EXOCAD-Amann Girrbach group (45.3 ± 4.8 µm), followed by the 3Shape-Roland group (57.2 ± 5.1 µm), and largest in the CEREC group (69.5 ± 6.3 µm). Internal fit values followed a similar trend: EXOCAD-Amann Girrbach (82.6 ± 6.9 µm), 3Shape-Roland (94.2 ± 7.4 µm), and CEREC (108.5 ± 8.1 µm). Statistically significant differences were observed among all groups ( P < 0.001). Conclusion: The choice of CAD/CAM system significantly affects the marginal adaptation and internal fit of zirconia crowns. The EXOCAD-Amann Girrbach combination yielded superior outcomes and may be recommended for clinical applications requiring high precision.
No takes yet. Share an insight, caveat, or question.
Kalsekar et al. (2025) studied this question.