Displacement chromatography of proteins was successfully carried out in both hydrophobic interaction and reversed-phase chromatographic systems using low-molecular weight displacers. The displacers employed for hydrophobic displacement chromatography were water soluble, charged molecules containing several short alkyl and/or aryl groups. Spectroscopy was employed to verify the absence of structural changes to the proteins displaced on these hydrophobic supports. Displacement chromatography on a reversed-phase material was employed to purify a growth factor protein from its closely related variants, demonstrating the high resolutions that can be achieved by hydrophobic displacement chromatography. This process combines the high-resolution/high-throughput characteristics of displacement chromatography with the unique selectivity of these hydrophobic supports and offers the chromatographic engineer a powerful tool for the preparative purification of proteins.
No takes yet. Share an insight, caveat, or question.
Shukla et al. (2000) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: