INTRODUCTION: In this research the behavior of coronary arteries has been studied with symmetric and asymmetric consecutive stenosis, and grafted vessels. METHODS: The incompressible Navier-Stokes and energy equations were discretized with second-order upwind method. Assumptions such as Newtonian fluid, wall rigidity and steady-flow were used. RESULTS: All the calculations showed the same results with Newtonians and non- Newtonian fluids. It was found that the possibility of stenosis be reduced by increasing the graft angle. However, there exists further stenosis possibility. Among the three graft angles 20, 30 ˚ and 40, the 30 ˚ was found to be the reliable ones. CONCLUSION: Based on these findings, it can be deduced that there would be a high risk of further atherosclerosis when the first stenose has the maximum percentage.
No takes yet. Share an insight, caveat, or question.
Razavi et al. (2011) studied this question.
Synapse has enriched one closely related paper. Consider it for comparative context: