Answers are grounded in this paper and cite their sources.
We show experiments proving the feasibility of scanning fluorescence microscopy by three-photon excitation. Three-photon excitation fluorescence axial images are shown of polystyrene beads stained with the fluorophore 2,5-bis(4-biphenyl)oxazole (BBO). Three-photon excitation is performed at an excitation wavelength of 900 nm and with pulses of 130 fs duration provided by a mode-locked titanium sapphire laser. Fluorescence is collected between 350 and 450 nm. The fluorescence image signal features a third-order dependence on the excitation power, also providing intrinsic 3-D imaging. The resolution of a three-photon excitation microscope is increased over that of a comparable two-photon excitation microscope.
No takes yet. Share an insight, caveat, or question.
Stefan W. Hell (1996) studied this question.