Answers are grounded in this paper and cite their sources.
In AC microgrid systems, technical issues resulting from the power control effect are the power control method efficiency and the filter resonance since voltage-frequency interference and filtering resonance may cause significant control input reduction and oscillation. A simple and robust solution is to regulate active power flow by adding an optimal passive damping resistor. The optimal LCL filter parameterization process in this paper provides an innovative approach to obtain the optimal quality factor and the optimal damping resistor. The amplitude responses of resonant frequency and high frequency are involved in the cost function. Simulations of various cases are conducted in MATLAB/Simulink. The key advantages of this procedure include flattened admittance peak, weakened high frequency decay, and less damping loss. Through the method in this paper, the optimal passive-damped filter parameters can be calculated in an efficient manner, while the power can be regulated and tracked in a simplified way, and the performance of the control strategy is improved.
No takes yet. Share an insight, caveat, or question.
Tang et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: