Key result
Visual continuous systolic feedback doubles systolic pressure reduction to ~4 mmHg versus auditory feedback.
Why the study?
Blood pressure presentation mode and personality are likely to influence biofeedback outcome, but their effects on blood pressure self-manipulation capability are unclear.
Does visual continuous systolic feedback improve systolic pressure reduction compared to auditory feedback in normotensive subjects?
RCT (n=36)
randomly assigned
Does visual continuous systolic feedback improve systolic pressure reduction compared to auditory feedback in normotensive subjects?
Visual feedback is more effective than auditory feedback for blood pressure self-manipulation, and psychological characteristics significantly influence this capability.
Answers are grounded in this paper and cite their sources.
Visual feedback may be preferred for BP biofeedback in normotensives; extends sensory-modality comparisons in self-regulation trials.
Blood pressure presentation mode and personality are likely to influence biofeedback outcome. Thirty-six normotensive subjects were randomly assigned to visual or auditory continuous systolic feedback. "Distracting speech" and "broad band noise" were also superimposed and the effect on the biofeedback response was investigated. Psychological influence was also investigated. Systolic pressure reduction of 4 +/- 4.3 mmHg (visual, p = .04) and 5 +/- 5.5 mmHg (visual + auditory, p = .03) were achieved compared with auditory feedback (2 +/- 4.7 mmHg), which was less effective. The addition of noise or speech had no effect on the systolic response, but speech adversely affected diastolic reduction (p = .04). Mood (p = .003) was associated with systolic lowering, whereas increased trait anxiety (p = .06) and expectation (p = .03) had trends for opposite effects. Increased anger-hostility, state-anxiety, and expectation (p = .06) had links with systolic raising capability. We conclude that feedback modality and psychological characteristics have implications for studies investigating blood pressure manipulation capability.
No takes yet. Share an insight, caveat, or question.
S et al. (1998) conducted an RCT in normotensive (n=36). Visual continuous systolic feedback vs. Auditory continuous systolic feedback was evaluated on Systolic pressure reduction (p=0.04). Visual continuous systolic feedback achieved a greater systolic pressure reduction compared with auditory feedback.
Synapse has enriched 10 related papers. Consider them for comparative context: